MANTENANCE and SERVICE for Denjoy® Root Canal Joypex 5 Apex

Today, we would like to share the MANTENANCE and SERVICE of one of Apex Locator, Denjoy® Root Canal Joypex 5 Apex Locator, to you sequentially.
 
a. MANTENANCE
 

The device is maintaained free of charge and doesn't require any routine maintenance within warranty period. The device cannot be repaired.

Dispose it if there is any problem.
Do not modify and disassemble the device.
This instrument described below has been fully inspected and confronts to the current products specification.
This instrument is guaranteed for its designated use, against original defects in materials and workmanship for a period of 12 months from date of purchase.
Products warranty or service will not be extended if
(1)  the product is repaired, modified, misused, disassembled, or using the parts are not provided by the manufacturer, (2) The serial number of the product is defaced or missing.
 
b. CLEANING AND DISINFECTION
 
MAIN BODY CLEANING INSTRUCTION
 
When the surface of main body is polluted, please rub the surface with dry soft cloth ONLY.
REMARKS: Any liquid lotion like ethanol, banana oil and light oil are not allowed.
 
TESTING WIRE CLEANING INSTRUCTION
 
Please wipe the testing wire with the soft cloth stained with ethanol and reuse it after it is completely dry.
 
ELECTRODE AND FILE HOLDER DISINFECTION INSTRUCTION
 
The front part of the file holder, which is easily get polluted with rubbish and liquid medicine, should be disinfected by the ethanol.
 
Stainless electrode and file holder should be disinfected at temperature 121for 20 minutes and disinfection by autoclave is preferred.
 
c. BATTERY REPLACEMENT
 
When the battery no longer holds a charge, it should be replaced by 5 pieces of 1.5V DC AAA dry Li-on battery. The batteries are recyclable. Remove the old battery from battery compartment and follow your local recycling guidelines.
 
TOUBLESHOOTING GUIDE
 
Question: After switch on the machine, the LCD screen has no reaction.
Answer:
a. Check that the 5pcs dry batteries are fixed properly.
b. Check that the power of the battery is in sufficient supply.
 
Question: No alert
Answer:
a. Check the alert adjustor button of panel on top of unit.
b. The file has not reached the point less than 2mm at which the machine will give an alert.
 
Question: NO changes or incorrect reading on the LCD screen
Answer:
a. Do not clip the file with the holder firstly and switch on the machine secondly.
b. Remember to hang the stainless electrode up at any side of the sufferer's mouth.
c. Check testing wire connections both at unit and at AC outlet to be sure they are properly seated.
d. The mental part of the file holder may be polluted or corroded.
 
IX: ENVIRONMENTAL REQUIREMENTS OPERATING CONDITIONS
 
Ambient temperature: 10~ 40
Relative humidity range: 10% ~ 93%
Atmospheric pressure: 86KPa~ 1006Kpa
 
STORAGE AND SHIPPING CONDITIONS
 
Ambient temperature: 10~ 40
Relative humidity range: 10% ~ 93%
Atmospheric pressure: 86KPa~ 1006KPa
Equipment is not suitable for storage in the presence of sunlight, rain, dust, corrosive gasoline and volatile without poor ventilation.
Transportation is applicable to all common methods.
 